Missing navigation space for subject area
Error Codes: OPR4ONWY:U9IM8TAC:OI2DL65P:OI2DL65P
State: HY000. Code: 10058. [NQODBC] [SQL_STATE: HY000] [nQSError: 10058] A general error has occurred. [nQSError: 43113] Message returned from OBIS. [nQSError: 15002] Missing navigation space for subject area…. (HY000)
Cause of the Error:
1. If you create an initialization box with non- logical query it may stop or hang the services of BI.
2. Some times over load of executing from Admin Tool also it will cause.
3. Database may not retrieve the data according to the query used in BI.
4. In BMM layer or Physical layer joins also may cause this error.
Solutions:
1. Check all the services of BI.
2. If anything got down restart the services then check the report.
3. If any of the measure column from the subject area if greyed out, then just edit the measure logical column and see the report.
4. Check the joins are in proper.
Screen Shots:
Missing navigation space for subject area |
Comments
Post a Comment